The JS Type Exhaust Fan is engineered by POPULA to provide a high-performance ventilation solution for demanding industrial environments. As a direct source manufacturer with decades of expertise, we ensure this unit delivers high air flow and significant electricity savings while maintaining a low noise profile.
Advanced Features of the JS Type Exhaust Fan
- Efficient Ventilation: Designed for optimal sunstroke prevention, making it an ideal choice for large-scale factory cooling.
- Easy Installation: Features a simplified structure for quick setup and minimal maintenance requirements.
- Industrial Durability: Built to comply with rigorous standards for deployment in warehouses, greenhouses, and poultry houses.
Core Operating Conditions:
The JS Type Exhaust Fan is designed to safely transport non-flammable, low-corrosive gases under the following environmental limits: Maximum temperature ≤ 50°C, Relative humidity ≤ 80%, and Dust/Solid impurities ≤ 100mg/m³.
Parameters
JS-II Exhaust Fan (Motor Directly Driven Type / A-Type Square Type)
| Model(Nº) | Power(kW) | Voltage(V) | Rotation(r/min) | Volume(m³/h) | Noise dB(A) | Remarks |
|---|---|---|---|---|---|---|
| JS-II-4A | 0.37 | 220/380 | 1400 | 7200 | ≤73 | With louver \ with front-and-back protective net |
| JS-II-5A | 0.55 | 220/380 | 1400 | 8600 | ≤75 | With louver \ with front-and-back protective net |
| JS-II-6A | 0.25 | 220/380 | 720 | 17000 | ≤70 | With louver \ with front-and-back protective net |
| JS-II-8A | 0.4 | 220/380 | 520 | 23000 | ≤71 | With louver \ with front-and-back protective net |
| JS-II-9A | 0.55 | 220/380 | 520 | 27500 | ≤73 | With louver \ with front-and-back protective net |
| JS-II-10A | 0.55 | 380 | 460 | 32000 | ≤74 | With louver \ with front-and-back protective net |
| JS-II-12A | 0.75 | 380 | 460 | 37000 | ≤75 | With louver \ with front-and-back protective net |
| JS-II-13A | 1.1 | 380 | 460 | 44500 | ≤78 | With louver \ with front-and-back protective net |
JS-II Exhaust Fan (Belt Driven Type / C-Type Square Type)
| Model(Nº) | Power(kW) | Voltage(V) | Rotation(r/min) | Volume(m³/h) | Noise dB(A) | Remarks |
|---|---|---|---|---|---|---|
| JS-II-7C | 0.55 | 220/380 | 640 | 18000 | ≤71 | With louver \ with front-and-back protective net |
| JS-II-8C | 0.55 | 220/380 | 520 | 23000 | ≤71 | With louver \ with front-and-back protective net |
| JS-II-9C | 0.75 | 220/380 | 520 | 27500 | ≤73 | With louver \ with front-and-back protective net |
| JS-II-10C | 0.75 | 220/380 | 460 | 32000 | ≤74 | With louver \ with front-and-back protective net |
| JS-II-12C | 1.1 | 220/380 | 460 | 37000 | ≤75 | With louver \ with front-and-back protective net |
| JS-II-13C | 1.1 | 220/380 | 460 | 44500 | ≤78 | With louver \ with front-and-back protective net |
| JS-II-14C | 1.5 | 220/380 | 520 | 55000 | ≤78 | With louver \ with front-and-back protective net |
siz
C-Type Louvered Window Installation Dimension Table
| Model | L | B | H | L1 | B1 | H | N-M | Impeller Dia(φ) | Weight(kg) |
|---|---|---|---|---|---|---|---|---|---|
| 7C | 902 | 342 | 900 | 600 | 133 | 800 | 8-M8 | 680 | 39 |
| 8C | 982 | 342 | 900 | 600 | 133 | 800 | 8-M8 | 780 | 41 |
| 9C | 1045 | 392 | 1160 | 735 | 175 | 8 | 8-M8 | 965 | 46.5 |
| 10C | 1122 | 342 | 920 | 735 | 133 | 8 | 8-M8 | 1040 | 54 |
| 12C | 1238 | 420 | 1200 | 795 | 235 | 8 | 8-M8 | 1220 | 69 |
| 13C | 1402 | 1480 | 1200 | 800 | 1260 | 8 | 12-M8 | 1260 | 79 |
A-Type with Louver Installation Dimension Table
| Model(Nº) | L | B | H | L1 | B1 | H1 | N-M | Impeller Φ(mm) | Weight(kg) |
|---|---|---|---|---|---|---|---|---|---|
| 4A | 502 | 342 | 502 | – | – | – | – | 395 | 18 |
| 5A | 602 | 342 | 602 | – | – | – | – | 495 | 22 |
| 6A | 752 | 342 | 750 | – | – | – | 8-M8 | 580 | 32 |
| 8A | 982 | 372 | 980 | 600 | 210 | 600 | 8-M8 | 780 | 45 |
| 9A | 1052 | 372 | 1050 | 660 | 220 | 660 | 8-M8 | 880 | 50 |
| 10A | 1112 | 372 | 1110 | 660 | 220 | 660 | 8-M8 | 965 | 55 |
| 12A | 1222 | 402 | 1220 | 795 | 250 | 795 | 8-M8 | 1040 | 72 |
| 13A | 1383 | 402 | 1381 | 600 | 250 | 795 | 8-M8 | 1220 | 86.5 |
A/C-Type with Front & Back Protective Net Installation Dimension Table
| Model(Nº) | L | B | H | L1 | B1 (A-Type) | B1 (C-Type) | H1 | N-M | Impeller Φ(mm) | Weight(kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| 6A | 752 | 282 | 750 | 600 | 210 | – | 600 | 8-M8 | 580 | 28 |
| 7C | 902 | 332 | 900 | 600 | 210 | 133 | 600 | 8-M8 | 680 | 34 |
| 8A/8C | 982 | 332 | 980 | 600 | 210 | 133 | 600 | 8-M8 | 780 | 40/36.5 |
| 9A/9C | 1052 | 332 | 1050 | 660 | 220 | 133 | 660 | 8-M8 | 880 | 43/39 |
| 10A/10C | 1112 | 332 | 1110 | 660 | 220 | 133 | 660 | 8-M8 | 965 | 48/42 |
| 12A | 1222 | 362 | 1220 | 795 | — | 133 | 795 | 8-M8 | 1040 | 62.5 |
| 12C | 1222 | 332 | 1220 | 795 | – | 133 | 795 | 8-M8 | 1040 | 46 |
| 13A | 1383 | 362 | 1381 | 795 | 250 | – | 795 | 8-M8 | 1220 | 76 |
| 13C | 1383 | 332 | 1381 | 795 | 250 | – | 795 | 8-M8 | 1220 | 52 |
| 14C | 1480 | 372 | 1480 | 1060 | – | 133 | 1060 | 12-M8 | 1260 | 66 |
Technical Illustration

Get a quote
သင့်အတွက် အခက်အခဲကင်းပြီး တာဝန်မရှိသော တိုင်ပင်ဆွေးနွေးမှုကို ယနေ့ပင် စတင်လိုက်ပါ။.
သင်သည် တိကျသော လေစီးဆင်းမှု သို့မဟုတ် static pressure data များကို ပေးရန် မလိုအပ်ပါ။ အလုပ်ရုံအရွယ်အစား၊ အပူချိန်အခြေအနေများ သို့မဟုတ် ဖုန်မှုန့်အဆင့်များကဲ့သို့သော သင်ရင်ဆိုင်နေရသော လေဝင်လေထွက်ဆိုင်ရာစိန်ခေါ်မှုများကို မျှဝေလိုက်ရုံဖြင့် ကျွန်ုပ်တို့၏အင်ဂျင်နီယာများသည် ရှုပ်ထွေးသောတွက်ချက်မှုများနှင့် မော်ဒယ်ရွေးချယ်မှုအားလုံးကို သင့်အတွက် ကိုင်တွယ်ပေးပါလိမ့်မည်။ ယနေ့တွင် ပေါ့ပေါ့ပါးပါး၊ တာဝန်မရှိသော ကနဦးတိုင်ပင်ဆွေးနွေးမှုကို စတင်လိုက်ပါ။.